<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IMAX LAB</title>
	<atom:link href="https://imaxlab.lt/en/feed/" rel="self" type="application/rss+xml" />
	<link>https://imaxlab.lt/en/</link>
	<description>Private and modular home construction and engineering systems in Vilnius County</description>
	<lastBuildDate>Thu, 22 Oct 2026 10:36:35 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>Monobloc vs Split Heat Pumps: Which Should You Choose Under the 2027 EU Rules?</title>
		<link>https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/</link>
					<comments>https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/#respond</comments>
		
		<dc:creator><![CDATA[agency-admin]]></dc:creator>
		<pubDate>Thu, 22 Oct 2026 10:35:43 +0000</pubDate>
				<category><![CDATA[Heating & Ventilation]]></category>
		<guid isPermaLink="false">https://imaxlab.lt/?p=332</guid>

					<description><![CDATA[<p>How monobloc and split air-to-water heat pumps differ, how to protect a monobloc from freezing, and what the 2027 EU rules actually change.</p>
<p>The post <a href="https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/">Monobloc vs Split Heat Pumps: Which Should You Choose Under the 2027 EU Rules?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">With 2027 approaching, you often hear that “from 2027 only monobloc heat pumps will be allowed”. That is not true. The EU rules restrict refrigerants by their global warming potential (GWP), equipment category and capacity&nbsp;– not the type of heat pump. Both monobloc and split air-to-water heat pumps will still be placed on the market as long as they meet the requirements.</p>



<p class="wp-block-paragraph">This article explains the practical differences: where the refrigerant circuit is, what runs through the wall, how to deal with the risk of freezing in a Lithuanian winter, how installation differs and what to discuss with your installer.</p>



<h2 class="wp-block-heading">Short answer: which is better?</h2>



<ul class="wp-block-list">
<li><strong>Neither is better across the board.</strong> Both can be the right choice&nbsp;– it depends on the layout of the house, where the outdoor unit can go, the distance to the plant room and the specific model.</li>



<li><strong>Monobloc:</strong> the whole refrigerant circuit sits in the outdoor unit and heating water runs into the house. No refrigerant connections are made on site, but the water outside needs manufacturer-approved freeze protection.</li>



<li><strong>Split:</strong> refrigerant pipes connect the outdoor and indoor units, and the water stays inside the building. The refrigerant connections must be made by a certified technician.</li>



<li><strong>Efficiency depends on the model</strong>, not on whether the unit is a monobloc or a split.</li>



<li><strong>From 2027</strong>, the refrigerants allowed in new equipment change, but neither type is banned. More in our article <a href="https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/">“R32 vs R290 heat pumps: what changes under EU rules in 2027?”</a>.</li>
</ul>



<h2 class="wp-block-heading">What is a monobloc heat pump?</h2>



<p class="wp-block-paragraph">In a monobloc, the whole refrigerant circuit&nbsp;– compressor, heat exchangers and refrigerant lines&nbsp;– is assembled and charged at the factory inside one outdoor unit. The outdoor unit heats water, which flows through pipes into the building and back. Inside there is usually an indoor module with the controller, a circulation pump or a hot-water cylinder; what exactly depends on the model.</p>



<p class="wp-block-paragraph">The EU F-gas Regulation calls this self-contained equipment: a factory-made system whose refrigerant-containing parts are not connected on site. The number of boxes is not what counts. Some manufacturers offer two-part systems (sometimes called “hydro split”) with only water between the units. If the refrigerant circuit is not connected on site, it works on the monobloc principle.</p>



<h3 class="wp-block-heading">Advantages and limitations</h3>



<ul class="wp-block-list">
<li><strong>Installation:</strong> the installer connects water pipes while the refrigerant circuit stays sealed. According to one manufacturer, no refrigerant certificate is needed to install a monobloc.</li>



<li><strong>Water outside:</strong> the outdoor pipes need good insulation and a freeze-protection plan.</li>



<li><strong>Distance:</strong> the longer the outdoor water run, the greater the heat loss, so the outdoor unit usually stands close to the plant room.</li>



<li><strong>R290 monoblocs:</strong> manufacturers define a safety zone around the outdoor unit that must be free of windows, doors, ventilation openings and ignition sources.</li>
</ul>



<h2 class="wp-block-heading">What is a split heat pump?</h2>



<p class="wp-block-paragraph">In a split air-to-water system the refrigerant circuit is divided: the outdoor unit usually holds the compressor and evaporator, and the indoor unit holds a heat exchanger where the refrigerant passes its heat to the heating water. The units are linked by refrigerant pipes that the installer connects on site. The heating water circulates only inside the building.</p>



<ul class="wp-block-list">
<li><strong>Qualifications:</strong> only certified technicians may work on an F-gas refrigerant circuit, and equipment with F-gases that is not hermetically sealed may only be sold to an end user with evidence that a certified company will install it (Articles 10 and 11 of the Regulation).</li>



<li><strong>Distances:</strong> the manufacturer sets the maximum pipe length and height difference. For example, <a href="https://www.vaillant.lt/patarimas/susipazinkite-su-technologijomis/silumos-siurbliai/mono-pries-split/">one manufacturer’s split system</a> allows up to 40 m of pipe and a 30 m height difference&nbsp;– other models may differ.</li>



<li><strong>Flexibility:</strong> the outdoor unit can often stand further from the plant room, for example where its noise will disturb less.</li>



<li><strong>Servicing:</strong> tight refrigerant joints are the key measure of installation quality, and whether periodic leak checks are required depends on the refrigerant charge expressed in CO₂ equivalent.</li>
</ul>



<figure class="wp-block-image size-full"><img fetchpriority="high" decoding="async" width="1763" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-scaled.webp" alt="Diagram: in a monobloc the refrigerant circuit stays in the outdoor unit and heating water flows through the wall to the indoor module; in a split system refrigerant pipes run through the wall to an indoor unit with a heat exchanger" class="wp-image-321" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-scaled.webp 1763w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-207x300.webp 207w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-705x1024.webp 705w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-768x1115.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-1058x1536.webp 1058w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-connection-diagram-1410x2048.webp 1410w" sizes="(max-width: 1763px) 100vw, 1763px" /><figcaption class="wp-element-caption">With a monobloc, heating water passes through the wall; with a split system, refrigerant does.</figcaption></figure>



<h2 class="wp-block-heading">Monobloc vs split: the main differences</h2>



<figure class="wp-block-table"><table><thead><tr><th></th><th>Monobloc</th><th>Split air-to-water</th></tr></thead><tbody><tr><td>Refrigerant circuit</td><td>Outdoor unit, sealed at the factory</td><td>Both units, connected on site</td></tr><tr><td>Through the wall</td><td>Water pipes</td><td>Refrigerant pipes</td></tr><tr><td>Water outdoors</td><td>Yes&nbsp;– needs frost protection</td><td>Usually not</td></tr><tr><td>Installation</td><td>Water circuit and electrics</td><td>Refrigerant joints by a certified technician</td></tr><tr><td>Unit spacing</td><td>Limited by heat loss and the manual</td><td>Within the maker’s pipe length and height limits</td></tr><tr><td>New units from 2027</td><td>GWP &lt; 150 up to 50&nbsp;kW</td><td>Up to 12&nbsp;kW: GWP &lt; 150; above: R32 until 2033</td></tr></tbody></table><figcaption class="wp-element-caption">Typical differences. The manufacturer specifies the requirements for each model.</figcaption></figure>



<h2 class="wp-block-heading">Installation and servicing: what to know</h2>



<p class="wp-block-paragraph">Either way you need space for the outdoor unit with free airflow, condensate drainage that will not freeze in winter, and easy access for servicing. Both types also need power and control cabling.</p>



<ul class="wp-block-list">
<li><strong>Monobloc:</strong> the key points are the water run through the wall, its insulation and freeze protection. The wall openings are usually larger than for refrigerant lines.</li>



<li><strong>Split:</strong> the key point is a properly connected and tested refrigerant circuit. The indoor unit with the heat exchanger goes in the plant room.</li>



<li><strong>Heating system:</strong> in both cases heat reaches the rooms through underfloor heating, radiators or fan coil units. We lay underfloor heating pipes together with the <a href="https://imaxlab.lt/en/services/plumbing-utility-connections/">plumbing work</a>.</li>



<li><strong>Servicing:</strong> both types need the servicing the manufacturer specifies, and only qualified technicians may work on the refrigerant circuit.</li>
</ul>



<h2 class="wp-block-heading">Freezing risk in a Lithuanian winter</h2>



<p class="wp-block-paragraph">This is one of the most important practical differences. In a monobloc, water sits in the outdoor unit and the outdoor pipes. While the unit runs and the water circulates, it does not freeze. But if circulation stops in frost&nbsp;– during a power cut, a fault or when the unit is switched off&nbsp;– the water outside can freeze and damage the equipment.</p>



<p class="wp-block-paragraph">That is why freeze protection for a monobloc has to be planned in advance. Manufacturers offer different solutions:</p>



<ul class="wp-block-list">
<li><strong>System separation.</strong> An intermediate heat exchanger is fitted in the indoor module and the outdoor circuit is filled with a water and antifreeze mix. <a href="https://professional.vaillant.co.uk/downloads/aproducts/renewables-1/arotherm-plus/arotherm-plus-vwl-35-75-a-s2-installation-operation-manual-0020330791-03-2806789.pdf">One manufacturer’s manual</a> states that the outdoor unit is then protected even when switched off or during a power cut.</li>



<li><strong>Glycol in the whole circuit.</strong> <a href="https://www.daikin.eu/content/dam/document-library/Installer-reference-guide/heat/air-to-water-heat-pump-low-temperature/eblq-c2v3/EBLQ-C2V3_4PEN598847-1_2019_10_Installer%20reference%20guide_English.pdf">Another manufacturer’s manual</a> protects the water circuit with glycol, but notes that glycol lowers the unit’s permitted operating limits.</li>



<li><strong>Continuous operation or draining.</strong> Without system separation, manufacturers generally require the unit to keep running in frost, and if that cannot be guaranteed, a professional should drain the system. For longer power cuts, backup power or other manufacturer-approved safeguards can be considered.</li>



<li><strong>Insulation</strong> reduces heat loss but does not prevent freezing if circulation stops for long.</li>
</ul>



<p class="wp-block-paragraph">The manufacturer specifies the method and the installer chooses it for the route, location and reliability of the power supply. In a split system there is usually no heating water outdoors, so this risk does not arise&nbsp;– but it does not heat without power either, and the indoor water circuit must also be in a heated space.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="1759" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-scaled.webp" alt="Diagram: water in a monobloc’s outdoor unit and pipes can freeze if circulation stops; manufacturer-specified protection options" class="wp-image-322" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-scaled.webp 1759w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-206x300.webp 206w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-704x1024.webp 704w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-768x1117.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-1056x1536.webp 1056w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-freeze-protection-1408x2048.webp 1408w" sizes="auto, (max-width: 1759px) 100vw, 1759px" /><figcaption class="wp-element-caption">The manufacturer specifies the freeze-protection method&nbsp;– there is no single universal solution.</figcaption></figure>



<h2 class="wp-block-heading">Is a monobloc more efficient than a split?</h2>



<p class="wp-block-paragraph">Not in itself. Manufacturers point out that efficiency depends more on product quality, refrigerant properties, installation and servicing than on whether the unit is a monobloc or a split (<a href="https://www.vaillant.lt/patarimas/susipazinkite-su-technologijomis/silumos-siurbliai/mono-pries-split/">Vaillant</a>). When comparing models:</p>



<ul class="wp-block-list">
<li>compare seasonal efficiency (SCOP) at the same flow temperatures and climate conditions;</li>



<li>check the output and efficiency the unit achieves at low outdoor temperatures;</li>



<li>make sure the output suits the building’s heat demand and heating system;</li>



<li>compare noise levels and consider where the outdoor unit will stand.</li>
</ul>



<p class="wp-block-paragraph">Nor can the price difference be generalised. Installation cost depends on the length of the run, wall openings, freeze protection, refrigerant work, the indoor equipment and adapting the existing heating system.</p>



<h2 class="wp-block-heading">What changes in 2027?</h2>



<p class="wp-block-paragraph">From 1 January 2027, Annex IV of <a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573">Regulation (EU) 2024/573</a> prohibits placing on the market:</p>



<ul class="wp-block-list">
<li>new monobloc and other self-contained heat pumps up to 50&nbsp;kW containing F-gases with a GWP of 150 or more;</li>



<li>new split air-to-water heat pumps up to 12&nbsp;kW containing F-gases with a GWP of 150 or more.</li>
</ul>



<p class="wp-block-paragraph">For split air-to-water systems above 12&nbsp;kW, R32 (GWP 675) remains allowed until 2033; for split air-to-air systems up to 12&nbsp;kW the restriction applies from 2029. From 2032, monoblocs up to 12&nbsp;kW, and from 2035, split systems up to 12&nbsp;kW, may not contain any F-gases. All of these dates concern placing new equipment on the market: installed units do not have to be replaced.</p>



<p class="wp-block-paragraph">Both 2027 restrictions include an exception where it is required to meet safety requirements at the site. According to the European Commission’s explanation reported by the <a href="https://www.ehpa.org/wp-content/uploads/2024/11/F-Gas-regulation-guidelines_European-Heat-Pump-Association_November-2024.pdf">European Heat Pump Association (EHPA)</a>, the exception is assessed for the specific location, and equipment using it must be labelled accordingly.</p>



<h2 class="wp-block-heading">Will you still be able to buy a split heat pump after 2027?</h2>



<p class="wp-block-paragraph">Yes. The Regulation does not ban split systems&nbsp;– it restricts the refrigerants they use:</p>



<ul class="wp-block-list">
<li>split air-to-water units up to 12&nbsp;kW can still be placed on the market with refrigerants whose GWP is below 150. These may be R290 or low-GWP A2L refrigerants such as R454C, which the <a href="https://climate.ec.europa.eu/areas-action/fluorinated-greenhouse-gases/climate-friendly-alternatives-f-gases/air-conditioning_en">European Commission</a> lists among the alternatives for domestic heat pumps;</li>



<li>split systems above 12&nbsp;kW with R32 remain allowed until 2033;</li>



<li>units lawfully placed on the market before 2027 can still be sold and installed later, with documents to prove it.</li>
</ul>



<p class="wp-block-paragraph">Which models will be available in Lithuania cannot be predicted. Some manufacturers say they are developing split systems with R290 and R454C (<a href="https://www.daikin.co.uk/en_gb/knowledge-center/f-gas-regulation/air-to-water-heat-pumps.html">Daikin</a>), but these are plans, not guarantees.</p>



<h2 class="wp-block-heading">Which should you choose for a new or renovated home?</h2>



<ul class="wp-block-list">
<li><strong>Plant room on an outside wall, short run:</strong> a monobloc is often the simple option, provided freeze protection is planned and there is room for the outdoor unit (and, for R290, its safety zone).</li>



<li><strong>The outdoor unit needs to stand further away</strong> because of noise, neighbours or looks: a split system can offer more flexibility if the distance is within the manufacturer’s limits.</li>



<li><strong>No room for an R290 safety zone:</strong> consider another location or another system.</li>



<li><strong>Renovated house with radiators:</strong> what matters most is the water temperature needed in the coldest weather. That drives the choice of model more than the type of unit.</li>



<li><strong>New low-energy house:</strong> a small output is often enough, so for new equipment from 2027 the GWP &lt; 150 limit will apply whichever type you choose.</li>
</ul>



<p class="wp-block-paragraph">IMAX LAB installs and services heat pumps with an output of up to 16&nbsp;kW in Vilnius County, works with equipment from a range of manufacturers and helps choose it to suit the building and budget. Find out more about our <a href="https://imaxlab.lt/en/services/heating-ventilation-cooling/">heating and cooling solutions</a>.</p>



<h2 class="wp-block-heading">What to discuss with your installer before you decide</h2>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="1731" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-scaled.webp" alt="Six questions for the installer when choosing between monobloc and split: outdoor unit location, distance, freeze protection, refrigerant and output, refrigerant work, indoor equipment location" class="wp-image-323" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-scaled.webp 1731w, https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-203x300.webp 203w, https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-692x1024.webp 692w, https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-768x1136.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-1039x1536.webp 1039w, https://imaxlab.lt/wp-content/uploads/2026/10/questions-for-installer-monobloc-or-split-1385x2048.webp 1385w" sizes="auto, (max-width: 1731px) 100vw, 1731px" /><figcaption class="wp-element-caption">The answers to these questions decide which type suits a particular home.</figcaption></figure>



<ol class="wp-block-list">
<li>Where will the outdoor unit stand, and does that spot meet the noise, airflow and (for R290) safety-zone requirements?</li>



<li>How long will the water or refrigerant pipes be, and what height difference&nbsp;– are they within the manufacturer’s limits?</li>



<li>How will a monobloc be protected from freezing during a power cut, and which method does the manufacturer allow?</li>



<li>Which refrigerant and rated output&nbsp;– do the 2027 restrictions apply, and what documents will I receive?</li>



<li>Who will work on the refrigerant circuit, and do the technicians hold the required certificates?</li>



<li>Where will the indoor module or unit and the hot-water cylinder go, and will they be easy to service?</li>



<li>What servicing does the manufacturer require, and what are the warranty terms?</li>
</ol>



<h2 class="wp-block-heading">Frequently asked questions</h2>



<h3 class="wp-block-heading">Will all split heat pumps be banned from 2027?</h3>



<p class="wp-block-paragraph">No. From 2027, refrigerants with a GWP of 150 or more are not allowed in new split air-to-water units up to 12&nbsp;kW. Split systems with lower-GWP refrigerants, and split systems above 12&nbsp;kW with R32 (until 2033), will still be placed on the market.</p>



<h3 class="wp-block-heading">Can a monobloc heat pump freeze during a power cut?</h3>



<p class="wp-block-paragraph">It can, if the water outdoors stops circulating in frost for a long time and there is no protection. That is why you need a manufacturer-approved solution: system separation with antifreeze, glycol, backup power or other measures the manufacturer specifies.</p>



<h3 class="wp-block-heading">Is a split heat pump better for Lithuanian winters?</h3>



<p class="wp-block-paragraph">There is no water in its outdoor part, so the freezing risk outside is lower. But output and efficiency in the cold depend on the specific model, not the type, so compare the manufacturers’ data.</p>



<h3 class="wp-block-heading">Is R290 only used in monobloc heat pumps?</h3>



<p class="wp-block-paragraph">Not necessarily. R290 is currently common in monoblocs because their refrigerant circuit stays outside, but manufacturers are also developing split systems with R290 and other low-GWP refrigerants.</p>



<h3 class="wp-block-heading">Which type is cheaper to install?</h3>



<p class="wp-block-paragraph">There is no universal answer. The cost depends on the length of the run, wall openings, freeze protection, refrigerant work, indoor equipment and the existing heating system, so compare specific quotes.</p>



<h3 class="wp-block-heading">Does a monobloc need an indoor unit?</h3>



<p class="wp-block-paragraph">Usually yes: there is an indoor module with the controller, pump or hot-water cylinder. Which parts are needed depends on the model and the system.</p>



<h3 class="wp-block-heading">Which heat pump should I choose for a new energy-efficient home?</h3>



<p class="wp-block-paragraph">Such a home usually has a low heat demand, so both types can work. Choose by where the outdoor unit can go, the distance to the plant room, hot-water needs and the specific model’s data&nbsp;– and, for new equipment from 2027, a low-GWP refrigerant.</p>



<h2 class="wp-block-heading">Conclusion</h2>



<p class="wp-block-paragraph">The difference between a monobloc and a split comes down to what passes through the wall of the house: water or refrigerant. That drives the main differences&nbsp;– freeze protection, installation work, distances and installer qualifications. The 2027 rules change which refrigerants are allowed, but ban neither type. The best choice is the one that suits the particular house, site and heating system.</p>



<p class="wp-block-paragraph"><strong>Planning a new heating system?</strong> Send us the house design or floor plan&nbsp;– we will help you assess which type and model of heat pump suits your building and prepare a preliminary estimate. <a href="https://imaxlab.lt/en/contact/#enquiry">Send us an enquiry</a>.</p>



<h2 class="wp-block-heading">Sources</h2>



<ul class="wp-block-list">
<li><a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573">Regulation (EU) 2024/573 on fluorinated greenhouse gases</a>&nbsp;– Articles 3, 5, 10, 11, 13 and Annex IV.</li>



<li>European Commission, <a href="https://climate.ec.europa.eu/areas-action/fluorinated-greenhouse-gases/climate-friendly-alternatives-f-gases/air-conditioning_en">“Air conditioning”</a>&nbsp;– refrigerant alternatives and overview of the restrictions.</li>



<li>European Heat Pump Association, <a href="https://www.ehpa.org/wp-content/uploads/2024/11/F-Gas-regulation-guidelines_European-Heat-Pump-Association_November-2024.pdf">“The new F-gas Regulation: detailed guidelines”</a> (November 2024)&nbsp;– safety exception, rated capacity.</li>



<li>Vaillant, <a href="https://www.vaillant.lt/patarimas/susipazinkite-su-technologijomis/silumos-siurbliai/mono-pries-split/">“Mono prieš split”</a> (in Lithuanian) and <a href="https://professional.vaillant.co.uk/downloads/aproducts/renewables-1/arotherm-plus/arotherm-plus-vwl-35-75-a-s2-installation-operation-manual-0020330791-03-2806789.pdf">aroTHERM plus installation manual</a> (0020330791_03, sections 3.4 and 5.3).</li>



<li>Daikin, <a href="https://www.daikin.co.uk/en_gb/knowledge-center/f-gas-regulation/air-to-water-heat-pumps.html">“F-gas regulation: air-to-water heat pumps”</a> and <a href="https://www.daikin.eu/content/dam/document-library/Installer-reference-guide/heat/air-to-water-heat-pump-low-temperature/eblq-c2v3/EBLQ-C2V3_4PEN598847-1_2019_10_Installer%20reference%20guide_English.pdf">Altherma monobloc compact installer reference guide</a> (4P598847-1, 2019).</li>
</ul>



<p class="wp-block-paragraph">The legislation and sources were last checked on 22 October 2026. This article is for general information and is not legal advice.</p>
<p>The post <a href="https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/">Monobloc vs Split Heat Pumps: Which Should You Choose Under the 2027 EU Rules?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>R32 vs R290 Heat Pumps: What Changes Under EU Rules in 2027?</title>
		<link>https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/</link>
					<comments>https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/#comments</comments>
		
		<dc:creator><![CDATA[agency-admin]]></dc:creator>
		<pubDate>Thu, 15 Oct 2026 10:00:00 +0000</pubDate>
				<category><![CDATA[Heating & Ventilation]]></category>
		<guid isPermaLink="false">https://imaxlab.lt/?p=309</guid>

					<description><![CDATA[<p>From 2027 the EU restricts new R32 monobloc heat pumps and smaller split air-to-water units. What this means for heat pumps already installed, servicing, spare parts and choosing R290.</p>
<p>The post <a href="https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/">R32 vs R290 Heat Pumps: What Changes Under EU Rules in 2027?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">From 1 January 2027, new monobloc heat pumps up to 50&nbsp;kW and new split air-to-water heat pumps up to 12&nbsp;kW can no longer be placed on the EU market if their refrigerant has a global warming potential (GWP) of 150 or more. R32 is above that limit; R290 (propane) is not. Heat pumps already running on R32 are not affected: they can still be used, serviced and repaired.</p>



<p class="wp-block-paragraph">This article explains what the <a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573">EU F-gas Regulation (EU) 2024/573</a> actually requires, how R32 and R290 differ, which restrictions follow after 2027, and what to consider if you are planning a heat pump for a home in 2026 or 2027.</p>



<h2 class="wp-block-heading">Key points</h2>



<ul class="wp-block-list">
<li><strong>From 1 January 2027</strong>, new monobloc heat pumps up to 50&nbsp;kW and split air-to-water heat pumps up to 12&nbsp;kW using F-gases with a GWP of 150 or more may not be placed on the market, unless this is required to meet safety requirements at the site.</li>



<li><strong>R32</strong> (GWP 675) is caught by these rules; <strong>R290</strong> (GWP 0.02) is not.</li>



<li>The rules apply to <strong>placing new equipment on the market</strong>, not to using equipment that is already installed. A working R32 heat pump does not have to be replaced.</li>



<li>R32 heat pumps <strong>can still be serviced and topped up with refrigerant</strong>: the servicing ban only covers F-gases with a GWP of 2,500 or more.</li>



<li><strong>Spare parts</strong> for repairing existing equipment remain allowed, as long as the repair does not increase capacity or the refrigerant charge, or switch to a higher-GWP refrigerant.</li>



<li><strong>R290 is not automatically the better choice.</strong> The right unit depends on the building’s heat demand, the heating system, where the outdoor unit can go and the specific model.</li>
</ul>



<h2 class="wp-block-heading">What are R32 and R290?</h2>



<p class="wp-block-paragraph">The refrigerant circulates inside the heat pump: as it evaporates it absorbs heat from the outdoor air, and as it condenses it releases that heat to the heating system. The refrigerant affects how the unit is designed, which safety requirements apply and how EU law treats it.</p>



<p class="wp-block-paragraph"><strong>R32</strong> is difluoromethane, a hydrofluorocarbon (HFC). It is an F-gas, so the F-gas Regulation applies to it. The <a href="https://climate.ec.europa.eu/areas-action/fluorinated-greenhouse-gases/climate-friendly-alternatives-f-gases/air-conditioning_en">European Commission</a> lists R32 as one of the replacements for R410A in split systems.</p>



<p class="wp-block-paragraph"><strong>R290</strong> is propane, a natural hydrocarbon. It is not an F-gas, so the regulation’s GWP limits do not apply to it. Propane is, however, highly flammable, so equipment using it comes with its own safety and installation requirements.</p>



<h3 class="wp-block-heading">What GWP and safety class mean</h3>



<p class="wp-block-paragraph">GWP shows how much more a substance contributes to global warming over 100 years than the same amount of carbon dioxide. Annex I of the regulation gives R32 a GWP of 675; Annex VI gives propane 0.02. You may see slightly different figures elsewhere because they are calculated from different IPCC assessment reports. For the legal limits, the values in the regulation are the ones that count.</p>



<p class="wp-block-paragraph">The safety class describes toxicity and flammability. Both refrigerants are in the lower-toxicity group A. R32 is class A2L (lower flammability), R290 is class A3 (higher flammability). In other words, both come with safety requirements; for propane they are stricter.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="1616" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-scaled.webp" alt="R32 and R290 compared: R32 has a GWP of 675, safety class A2L and is an F-gas; R290 has a GWP of 0.02, safety class A3 and is not an F-gas; R32 is above the 2027 GWP limit of 150, R290 is not" class="wp-image-304" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-scaled.webp 1616w, https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-189x300.webp 189w, https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-646x1024.webp 646w, https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-768x1217.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-970x1536.webp 970w, https://imaxlab.lt/wp-content/uploads/2026/10/r32-vs-r290-comparison-gwp-safety-class-1293x2048.webp 1293w" sizes="auto, (max-width: 1616px) 100vw, 1616px" /><figcaption class="wp-element-caption">R32 and R290 compared. Sources: Regulation (EU) 2024/573, Annexes I, IV and VI; European Commission.</figcaption></figure>



<figure class="wp-block-table"><table><thead><tr><th></th><th>R32</th><th>R290</th></tr></thead><tbody><tr><td>Substance</td><td>difluoro­methane</td><td>propane</td></tr><tr><td>Formula</td><td>CH₂F₂</td><td>C₃H₈</td></tr><tr><td>F-gas</td><td>Yes (HFC)</td><td>No</td></tr><tr><td>GWP (100-year)</td><td>675</td><td>0.02</td></tr><tr><td>Safety class</td><td>A2L, lower flammability</td><td>A3, higher flammability</td></tr><tr><td>2027 restriction*</td><td>Applies</td><td>Does not apply</td></tr></tbody></table><figcaption class="wp-element-caption">* For new monobloc units up to 50&nbsp;kW and split air-to-water units up to 12&nbsp;kW. Sources: Regulation (EU) 2024/573, Annexes I, IV and VI; European Commission.</figcaption></figure>



<h2 class="wp-block-heading">Monobloc, split air-to-water and split air-to-air: what is the difference?</h2>



<p class="wp-block-paragraph">The dates depend not only on the refrigerant but also on the type of unit. The regulation distinguishes between self-contained equipment and split systems.</p>



<ul class="wp-block-list">
<li><strong>Monobloc.</strong> The whole refrigerant circuit is built into the outdoor unit at the factory. Only the heating water pipes enter the house, and no refrigerant connections are made on site. The regulation calls this self-contained equipment.</li>



<li><strong>Split air-to-water.</strong> The outdoor and indoor units are linked by refrigerant pipes that the installer connects on site. The indoor unit transfers the heat to water for underfloor heating, radiators or fan coil units, and for hot water.</li>



<li><strong>Split air-to-air.</strong> Units linked by refrigerant pipes heat or cool the room air directly&nbsp;– this is how a typical wall-mounted air conditioner works.</li>
</ul>



<p class="wp-block-paragraph">A monobloc with an indoor module or hot-water cylinder is still a monobloc as long as only water goes indoors. What matters is not the number of boxes but whether the refrigerant circuit is connected on site. We compare the two types in more detail in <a href="https://imaxlab.lt/en/monobloc-vs-split-heat-pumps/">“Monobloc vs split heat pumps: which should you choose?”</a>.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="1680" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-scaled.webp" alt="Diagram: in a monobloc unit the refrigerant circuit stays in the outdoor unit and only water enters the house; in a split air-to-water system refrigerant pipes run through the wall to the indoor unit" class="wp-image-306" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-scaled.webp 1680w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-197x300.webp 197w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-672x1024.webp 672w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-768x1170.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-1008x1536.webp 1008w, https://imaxlab.lt/wp-content/uploads/2026/10/monobloc-vs-split-air-to-water-diagram-1344x2048.webp 1344w" sizes="auto, (max-width: 1680px) 100vw, 1680px" /><figcaption class="wp-element-caption">With a monobloc, only heating water enters the house; with a split system, the refrigerant pipes do.</figcaption></figure>



<h2 class="wp-block-heading">What changes on 1 January 2027</h2>



<p class="wp-block-paragraph">Annex IV of the regulation lists equipment that may not be placed on the market from the dates shown. For heat pumps, two entries apply from 2027:</p>



<ul class="wp-block-list">
<li><strong>Monobloc and other self-contained heat pumps up to 50&nbsp;kW</strong> (point 8(b) and (d)) containing F-gases with a GWP of 150 or more.</li>



<li><strong>Split air-to-water systems with a rated capacity up to and including 12&nbsp;kW</strong> (point 9(b)) containing F-gases with a GWP of 150 or more.</li>
</ul>



<p class="wp-block-paragraph">Put simply, from 2027 new R32 monobloc units up to 50&nbsp;kW and new R32 split air-to-water heat pumps up to 12&nbsp;kW can no longer be placed on the market. For split air-to-water systems above 12&nbsp;kW, R32 remains allowed until 2033 (see below).</p>



<p class="wp-block-paragraph">How rated capacity is determined is set out in Commission <a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R2195">Implementing Regulation (EU) 2024/2195</a>: where equipment can have different functions, the rated capacity refers to its primary function, and where ecodesign legislation sets a calculation method, that method applies. So check the threshold against the manufacturer’s declared rated capacity for the specific model, and if a unit is close to 12&nbsp;kW, raise the question with the supplier.</p>



<h3 class="wp-block-heading">What “placing on the market” means</h3>



<p class="wp-block-paragraph">Placing on the market means supplying a unit to the EU market for the first time&nbsp;– for example, when a manufacturer or importer releases it for free circulation. Units lawfully placed on the market before 1 January 2027 can therefore still be sold afterwards. From one year after the ban date, anyone supplying them further needs evidence that they were placed on the market in time (Article 11(1)).</p>



<p class="wp-block-paragraph">If such a unit is put into operation after the ban date, the operator&nbsp;– in a private home usually the owner&nbsp;– must be able to show that it was placed on the market before that date, and keep the documents for at least five years (<a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573R(05)">Article 13(19) and (20)</a>). If you buy a remaining R32 unit from stock in 2027, ask the supplier for written confirmation.</p>



<h3 class="wp-block-heading">The safety exception</h3>



<p class="wp-block-paragraph">Both 2027 restrictions include an exception where it is required to meet safety requirements at the site of operation. For monobloc units, the regulation adds that if safety requirements do not allow a refrigerant with a GWP below 150, a limit of 750 applies. This covers specific situations; it is not a general option to choose R32. The operator has to hold evidence that safety requirements at the location rule out lower-GWP equipment, so the exception should only be relied on when it is clearly justified and documented.</p>



<h2 class="wp-block-heading">Later restrictions: 2029 to 2035</h2>



<p class="wp-block-paragraph">After 2027, the restrictions widen in stages. Below are the Annex IV dates relevant to heating and cooling. All of them concern placing new equipment on the market only.</p>



<figure class="wp-block-image size-full"><img loading="lazy" decoding="async" width="1506" height="2560" src="https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-scaled.webp" alt="Timeline of the EU F-gas Regulation Annex IV restrictions on new heat pumps and air conditioners from 2027 to 2035" class="wp-image-305" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-scaled.webp 1506w, https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-176x300.webp 176w, https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-602x1024.webp 602w, https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-768x1306.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-904x1536.webp 904w, https://imaxlab.lt/wp-content/uploads/2026/10/eu-f-gas-heat-pump-restrictions-2027-2035-1205x2048.webp 1205w" sizes="auto, (max-width: 1506px) 100vw, 1506px" /><figcaption class="wp-element-caption">Restrictions on placing new equipment on the market under Annex IV of Regulation (EU) 2024/573. The same data is in the table below.</figcaption></figure>



<figure class="wp-block-table"><table><thead><tr><th>From</th><th>Equipment and limit</th><th>Affects R32?</th></tr></thead><tbody><tr><td>1 Jan 2027</td><td>Monobloc and other self-contained units up to 50&nbsp;kW; GWP ≥&nbsp;150</td><td>Yes</td></tr><tr><td>1 Jan 2027</td><td>Split air-to-water up to 12&nbsp;kW; GWP ≥&nbsp;150</td><td>Yes</td></tr><tr><td>1 Jan 2029</td><td>Split air-to-air up to 12&nbsp;kW; GWP ≥&nbsp;150</td><td>Yes</td></tr><tr><td>1 Jan 2029</td><td>Split systems above 12&nbsp;kW; GWP ≥&nbsp;750</td><td>No (R32 GWP 675)</td></tr><tr><td>1 Jan 2030</td><td>Other self-contained equipment (above 50&nbsp;kW); GWP ≥&nbsp;150</td><td>Yes</td></tr><tr><td>1 Jan 2032</td><td>Monobloc and other self-contained units up to 12&nbsp;kW; any F-gas</td><td>Yes</td></tr><tr><td>1 Jan 2033</td><td>Split systems above 12&nbsp;kW; GWP ≥&nbsp;150</td><td>Yes</td></tr><tr><td>1 Jan 2035</td><td>Split systems up to 12&nbsp;kW; any F-gas</td><td>Yes</td></tr></tbody></table><figcaption class="wp-element-caption">Safety exceptions are not shown. Source: Regulation (EU) 2024/573, Annex IV, points 8 and 9.</figcaption></figure>



<p class="wp-block-paragraph">The regulation requires the European Commission to assess by 2030 whether suitable alternatives exist for bans that are not yet in force, particularly for split air conditioners and heat pumps (Article 35). The later dates could therefore be reviewed, but for now they are the ones that apply.</p>



<h2 class="wp-block-heading">Will an installed R32 heat pump become illegal?</h2>



<p class="wp-block-paragraph">No. The Annex IV bans apply to placing new equipment on the market. The regulation does not require lawfully bought and installed R32 heat pumps to be removed or replaced, so they can run for their full working life.</p>



<p class="wp-block-paragraph">If your R32 heat pump is working well, the 2027 changes alone are no reason to replace it. Base that decision on the unit’s condition, the cost of repairs and whether it still meets the needs of the house.</p>



<h2 class="wp-block-heading">Servicing, refrigerant and spare parts</h2>



<h3 class="wp-block-heading">Topping up and repairs</h3>



<p class="wp-block-paragraph">From 2026, Article 13 prohibits using F-gases with a GWP of 2,500 or more to service air-conditioning equipment and heat pumps. R32 has a GWP of 675, so this ban does not apply: R32 heat pumps can be serviced, repaired and topped up with refrigerant when needed.</p>



<p class="wp-block-paragraph">Only certified technicians may work on the refrigerant circuit, and only they&nbsp;– or companies employing them&nbsp;– may buy F-gases for this work (Articles 10 and 11). Whether your unit needs periodic leak checks depends on its refrigerant charge expressed in CO₂ equivalent (Article 5). The unit’s label or your installer can tell you.</p>



<h3 class="wp-block-heading">Spare parts</h3>



<p class="wp-block-paragraph">The regulation still allows parts to be supplied for repairing existing equipment after the ban dates, as long as the repair does not increase the unit’s capacity or F-gas charge, or switch to a higher-GWP refrigerant (Article 11(1)). Spare parts do not become illegal. How long a particular manufacturer keeps making them is up to that manufacturer, so it is worth asking before you buy.</p>



<h3 class="wp-block-heading">Will R32 get more expensive?</h3>



<p class="wp-block-paragraph">R32 itself is not banned, but the total quantity of HFCs that may be placed on the EU market is cut through quotas: in 2027–2029 it is roughly half the 2025–2026 level, and from 2050 it is zero (Annex VII). How this will affect the price and availability of R32 in Lithuania cannot be predicted with certainty&nbsp;– that is a market forecast, not a legal rule.</p>



<h2 class="wp-block-heading">Is R290 always the better choice?</h2>



<p class="wp-block-paragraph">Not always. R290’s advantage is its very low GWP: the F-gas Regulation’s market restrictions do not apply to it, so the Annex IV dates are not a concern for an R290 unit. But the refrigerant is not everything:</p>



<ul class="wp-block-list">
<li><strong>Efficiency depends on the model</strong>&nbsp;– the compressor, heat exchangers, controls and how well the unit is sized for the building. Compare the manufacturers’ seasonal performance figures at the same flow temperatures.</li>



<li><strong>Flow temperature.</strong> According to manufacturers’ data, some R290 models can deliver higher water temperatures, which can matter in a house with radiators. Check the data for the specific model rather than the refrigerant’s general reputation.</li>
</ul>



<p class="wp-block-paragraph">R290 is a forward-looking choice for a new monobloc, but it needs room for the safety zone, and the decision should rest on the building’s needs and the specific model’s data.</p>



<h2 class="wp-block-heading">R290 safety and installation</h2>



<p class="wp-block-paragraph">Propane is heavier than air. If the circuit leaks, escaping refrigerant can collect near the ground and form a flammable mixture with air. That is why manufacturers define a safety zone around the outdoor unit.</p>



<p class="wp-block-paragraph">For example, <a href="https://professional.vaillant.co.uk/downloads/aproducts/renewables-1/arotherm-plus/arotherm-plus-vwl-35-75-a-s2-installation-operation-manual-0020330791-03-2806789.pdf">one manufacturer’s monobloc installation manual</a> states that the protective zone must not contain windows, doors, light shafts, basement entrances or ventilation openings, or ignition sources such as sockets, switches and lights, and that the zone must not extend to neighbouring buildings or public traffic areas. The size and rules of the zone depend on the model and the type of installation&nbsp;– on the ground, on a wall or on a flat roof&nbsp;– so check them in the manual for the specific unit before choosing the location.</p>



<ul class="wp-block-list">
<li>A monobloc suits propane well: the refrigerant circuit stays in the outdoor unit and only water enters the house.</li>



<li>Work on the refrigerant circuit must be done by qualified technicians. The regulation provides for certification and training to cover alternative refrigerants, including natural ones, where relevant (Article 10).</li>



<li>Do not change the refrigerant in an existing unit: an R32 unit cannot safely be filled with propane, because the unit and its safety design are built for a specific refrigerant.</li>



<li>Do not later add openings, basement steps or electrical fittings inside the safety zone that would break the manufacturer’s requirements.</li>
</ul>



<h2 class="wp-block-heading">How to choose a heat pump for a home in Lithuania</h2>



<p class="wp-block-paragraph">The refrigerant is only one criterion. What matters far more is that the unit fits the specific building:</p>



<ul class="wp-block-list">
<li><strong>Heat loss.</strong> The output is sized for how much heat the building loses in the coldest weather, which depends on floor area, insulation, windows and airtightness. A unit that is too large or too small performs worse.</li>



<li><strong>Flow temperature and heating system.</strong> Underfloor heating usually runs at a lower temperature than radiators, and the lower the flow temperature, the easier it is for a heat pump to work efficiently. We lay underfloor heating pipes together with the <a href="https://imaxlab.lt/en/services/plumbing-utility-connections/">plumbing work</a>.</li>



<li><strong>Hot water.</strong> Cylinder size and how hot water is produced depend on the size of the household and how it uses water.</li>



<li><strong>Cold-weather performance.</strong> For Lithuanian winters, what matters is the output and efficiency the unit achieves at low outdoor temperatures, as stated in the manufacturer’s technical data.</li>



<li><strong>Noise.</strong> Compare sound power levels and consider the distance to bedroom windows and the neighbours.</li>



<li><strong>Space.</strong> The outdoor unit needs room, free airflow, condensate drainage and access for servicing&nbsp;– and, for R290, the safety zone.</li>



<li><strong>Electricity.</strong> A heat pump needs suitable power and control circuits, which are best planned together with the <a href="https://imaxlab.lt/en/services/electrical-installations/">electrical work</a>.</li>



<li><strong>Servicing.</strong> Consider who will service the unit and how, and how readily spare parts and manufacturer support are available.</li>
</ul>



<p class="wp-block-paragraph">IMAX LAB installs and services heat pumps with an output of up to 16&nbsp;kW in Vilnius County, works with equipment from a range of manufacturers and helps choose it to suit the building and the budget. Because we also install units above 12&nbsp;kW, it is worth knowing that different dates apply to split air-to-water systems up to 12&nbsp;kW and above 12&nbsp;kW. Find out more about our <a href="https://imaxlab.lt/en/services/heating-ventilation-cooling/">heating and cooling solutions</a>.</p>



<h2 class="wp-block-heading">Checklist for buying a heat pump in 2026–2027</h2>



<ol class="wp-block-list">
<li>Ask for an assessment of the heat demand and an explanation of why that output was chosen.</li>



<li>Find out whether the unit offered is a monobloc or a split system, and its rated capacity according to the manufacturer.</li>



<li>Check which refrigerant it uses and how much. This is shown on the unit’s label and in the technical data.</li>



<li>If you are offered an R32 monobloc or an R32 split air-to-water unit up to 12&nbsp;kW in 2027 or later, ask for written confirmation that it was placed on the market before 1 January 2027, and keep it.</li>



<li>For an R290 unit, check that the manufacturer’s safety zone fits at the planned location.</li>



<li>Compare seasonal performance at the same flow temperatures, cold-weather output, noise and hot-water production.</li>



<li>Check the warranty terms and the servicing the manufacturer requires.</li>
</ol>



<h3 class="wp-block-heading">Questions to ask your heat pump installer</h3>



<ul class="wp-block-list">
<li>How did you calculate my home’s heat demand, and what flow temperature are you planning for?</li>



<li>Why are you recommending this refrigerant and this type of unit?</li>



<li>Do the 2027 restrictions apply to this unit, and what documents will I receive?</li>



<li>Where will the outdoor unit go, and what safety zone or clearances does the manufacturer require?</li>



<li>Do your technicians hold the certificates needed to work with this type of refrigerant?</li>



<li>Who will service the unit, how often, and will spare parts be available?</li>



<li>Does this unit need periodic leak checks?</li>
</ul>



<h2 class="wp-block-heading">Frequently asked questions</h2>



<h3 class="wp-block-heading">Are all R32 heat pumps banned in the EU from 2027?</h3>



<p class="wp-block-paragraph">No. From 1 January 2027, new R32 monobloc units up to 50&nbsp;kW and new R32 split air-to-water heat pumps up to 12&nbsp;kW may not be placed on the market, subject to safety exceptions. For split air-to-air units up to 12&nbsp;kW the restriction applies from 2029, and for split systems above 12&nbsp;kW from 2033. Units already installed are not affected.</p>



<h3 class="wp-block-heading">Do I have to replace my existing R32 heat pump?</h3>



<p class="wp-block-paragraph">No. The regulation does not require lawfully installed equipment to be replaced. It can be used, serviced and repaired for its whole working life.</p>



<h3 class="wp-block-heading">Can an R32 heat pump still be topped up with refrigerant?</h3>



<p class="wp-block-paragraph">Yes. The servicing ban only covers F-gases with a GWP of 2,500 or more, and R32 has a GWP of 675. The work must be done by a certified technician.</p>



<h3 class="wp-block-heading">Will spare parts for R32 heat pumps still be available?</h3>



<p class="wp-block-paragraph">Yes. The regulation allows parts to be supplied for repairing existing equipment, as long as the repair does not increase capacity or the refrigerant charge, or switch to a higher-GWP refrigerant. How long a particular manufacturer makes parts is up to that manufacturer.</p>



<h3 class="wp-block-heading">Is R290 safe?</h3>



<p class="wp-block-paragraph">R290 units are designed to meet the safety requirements for flammable refrigerants. Whether an installation is safe depends on the unit being installed according to the manufacturer’s instructions, the safety zone being respected and the work being done by qualified technicians.</p>



<h3 class="wp-block-heading">Which refrigerant should I choose for a new home?</h3>



<p class="wp-block-paragraph">From 2027, new monobloc units and split air-to-water units up to 12&nbsp;kW can no longer be placed on the market with R32, so they use lower-GWP refrigerants such as R290. But the unit should be chosen first for the home’s heat demand, the heating system and where the outdoor unit can go; the refrigerant is one of those factors.</p>



<h3 class="wp-block-heading">Can any heat pump use R290?</h3>



<p class="wp-block-paragraph">No. The manufacturer chooses the refrigerant when designing the unit, so R290 is only used in units built for it. And not every site has room for the manufacturer’s safety zone&nbsp;– for example, where the only place for the outdoor unit is next to windows or an entrance.</p>



<h2 class="wp-block-heading">Summary</h2>



<p class="wp-block-paragraph">The 2027 changes affect which new heat pumps can be placed on the market, not the status of units already installed. R32 owners have no reason to worry: their units can be used, serviced and repaired. If you are planning a new system, the refrigerant matters less than correctly sized output, the right heating system, a suitable location and good installation.</p>



<p class="wp-block-paragraph"><strong>Planning a new heating system?</strong> Send us the house design or floor plan&nbsp;– we will help you assess which heat pump suits your building, propose a system design and prepare a preliminary estimate. Read more about <a href="https://imaxlab.lt/en/services/heating-ventilation-cooling/">heat pump selection and installation</a> or <a href="https://imaxlab.lt/en/contact/#enquiry">send us an enquiry</a>.</p>



<h2 class="wp-block-heading">Sources</h2>



<ul class="wp-block-list">
<li><a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573">Regulation (EU) 2024/573 on fluorinated greenhouse gases</a>&nbsp;– Articles 3, 5, 10, 11, 13 and 35; Annexes I, IV, VI and VII.</li>



<li><a href="https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573R(05)">Corrigendum to Regulation (EU) 2024/573</a> (24 March 2025)&nbsp;– Article 13(19).</li>



<li>European Commission, <a href="https://climate.ec.europa.eu/areas-action/fluorinated-greenhouse-gases/climate-friendly-alternatives-f-gases/air-conditioning_en">“Air conditioning”</a>&nbsp;– refrigerant GWP values and safety classes, overview of the restrictions.</li>



<li>European Commission, <a href="https://climate.ec.europa.eu/areas-action/fluorinated-greenhouse-gases/documentation/f-gas-legislation_en">“F-gas legislation”</a>&nbsp;– list of amendments and implementing acts.</li>



<li>Vaillant, <a href="https://professional.vaillant.co.uk/downloads/aproducts/renewables-1/arotherm-plus/arotherm-plus-vwl-35-75-a-s2-installation-operation-manual-0020330791-03-2806789.pdf">aroTHERM plus VWL 35/6–75/6 installation and maintenance instructions</a> (0020330791_03), section 4.1&nbsp;– example of a protective zone.</li>
</ul>



<p class="wp-block-paragraph">The legislation and any amendments were last checked on 22 October 2026. This article is for general information and is not legal advice.</p>
<p>The post <a href="https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/">R32 vs R290 Heat Pumps: What Changes Under EU Rules in 2027?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://imaxlab.lt/en/r32-vs-r290-heat-pumps-2027/feed/</wfw:commentRss>
			<slash:comments>1</slash:comments>
		
		
			</item>
		<item>
		<title>Gypsum, Lime-Cement or Clay Plaster: Which to Choose?</title>
		<link>https://imaxlab.lt/en/gypsum-lime-cement-or-clay-plaster/</link>
					<comments>https://imaxlab.lt/en/gypsum-lime-cement-or-clay-plaster/#respond</comments>
		
		<dc:creator><![CDATA[agency-admin]]></dc:creator>
		<pubDate>Thu, 08 Oct 2026 10:00:00 +0000</pubDate>
				<category><![CDATA[Interior Work]]></category>
		<guid isPermaLink="false">https://imaxlab.lt/?p=313</guid>

					<description><![CDATA[<p>How gypsum, lime-cement and clay plaster differ, where each works best and what to prepare before plastering.</p>
<p>The post <a href="https://imaxlab.lt/en/gypsum-lime-cement-or-clay-plaster/">Gypsum, Lime-Cement or Clay Plaster: Which to Choose?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>
]]></description>
										<content:encoded><![CDATA[
<p class="wp-block-paragraph">Plaster affects more than how walls and ceilings look. The mix determines how the surface copes with damp, how well it resists knocks, what finish it needs later and when the next trades can start. That is why it is worth choosing plaster for the conditions in each room rather than out of habit.</p>



<p class="wp-block-paragraph"><strong>In short:</strong> gypsum plaster is the usual choice for dry living spaces, lime-cement for damper areas and walls that take more wear, and clay plaster when you want natural materials. Many private houses use more than one mix.</p>



<h2 class="wp-block-heading">The three most common options</h2>



<h3 class="wp-block-heading">Gypsum plaster</h3>



<p class="wp-block-paragraph">Gypsum plaster is most often chosen for the living areas of a private house: rooms, hallways and stairwells. It gives a smooth surface that is usually easy to prepare for painting. Gypsum does not cope well with constant moisture, so where walls are regularly damp or directly wetted, choose a different mix or add extra protection.</p>



<h3 class="wp-block-heading">Lime-cement plaster</h3>



<p class="wp-block-paragraph">Lime-cement plaster is harder and tolerates moisture better, so it is often used in bathrooms, basements and plant rooms, and under tiles. Its surface is usually rougher, so it generally needs skimming before painting.</p>



<h3 class="wp-block-heading">Clay plaster</h3>



<p class="wp-block-paragraph">Clay plaster is chosen when natural materials are a priority. It is vapour-permeable and can absorb and release some of the room’s moisture. It is softer than lime-cement mixes and has its own requirements for application and finishing, so it is worth discussing in advance.</p>



<h2 class="wp-block-heading">What to consider when choosing</h2>



<ul class="wp-block-list">
<li><strong>Use of the room and moisture.</strong> Dry living spaces suit different mixes from a bathroom or basement.</li>



<li><strong>Substrate.</strong> Masonry, blocks and concrete absorb moisture differently, so the substrate needs to be assessed and properly prepared.</li>



<li><strong>Planned finish.</strong> Paint, tiles or decorative plaster each make different demands on how flat and firm the surface must be.</li>



<li><strong>Wear and tear.</strong> Walls in hallways, stairwells and commercial premises take more knocks, so a harder surface may be needed.</li>



<li><strong>Schedule.</strong> Plaster must dry before finishing. How long that takes depends on the mix, layer thickness, temperature and ventilation, so build drying time into the overall work plan.</li>
</ul>



<h2 class="wp-block-heading">Quick comparison</h2>



<figure class="wp-block-table"><table><thead><tr><th>Mix</th><th>Typical use</th><th>What to watch</th></tr></thead><tbody><tr><td>Gypsum</td><td>Dry living spaces</td><td>Not for constantly damp areas without extra protection</td></tr><tr><td>Lime-cement</td><td>Bathrooms, basements, plant rooms</td><td>Rougher surface, usually skimmed before painting</td></tr><tr><td>Clay</td><td>When natural materials are wanted</td><td>Softer surface, own application and finishing requirements</td></tr></tbody></table></figure>



<h2 class="wp-block-heading">Why machine plastering</h2>



<p class="wp-block-paragraph">With machine plastering, the mix is prepared and sprayed onto the wall by a plastering machine and then levelled with hand tools. The machine mixes the material evenly, which makes this method especially suitable for larger areas. Read more about how the work is done on our <a href="https://imaxlab.lt/en/services/machine-plastering/">machine plastering</a> page.</p>



<h2 class="wp-block-heading">What to do before plastering</h2>



<ul class="wp-block-list">
<li>Finish the electrical and plumbing runs, so that plastered walls do not have to be opened up later. More on our <a href="https://imaxlab.lt/en/services/electrical-installations/">electrical installations</a> and <a href="https://imaxlab.lt/en/services/plumbing-utility-connections/">plumbing</a> pages.</li>



<li>Install the windows.</li>



<li>Assess the substrate and, if necessary, prepare it following the instructions of the chosen mix’s manufacturer.</li>



<li>Make sure the rooms are kept at the temperature the manufacturer recommends and can be ventilated while the plaster dries.</li>
</ul>



<figure class="wp-block-image size-large"><img loading="lazy" decoding="async" width="2000" height="1500" src="https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje.webp" alt="Plastered corridor in the attic with electrical outlets prepared in the wall" class="wp-image-103" srcset="https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje.webp 2000w, https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje-300x225.webp 300w, https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje-1024x768.webp 1024w, https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje-768x576.webp 768w, https://imaxlab.lt/wp-content/uploads/2026/10/nutinkuotas-koridorius-pastogeje-1536x1152.webp 1536w" sizes="auto, (max-width: 2000px) 100vw, 2000px" /><figcaption class="wp-element-caption">Electrical outlets prepared in the wall before plastering. Photo of IMAX LAB work.</figcaption></figure>



<h2 class="wp-block-heading">Summary</h2>



<p class="wp-block-paragraph">There is no single best plaster. Private houses often combine several mixes: gypsum for living spaces and lime-cement for damper ones. If you are building a house or planning interior work, <a href="https://imaxlab.lt/en/contact/#enquiry">describe your rooms in an enquiry</a> – we will suggest a suitable solution and prepare a preliminary estimate.</p>
<p>The post <a href="https://imaxlab.lt/en/gypsum-lime-cement-or-clay-plaster/">Gypsum, Lime-Cement or Clay Plaster: Which to Choose?</a> appeared first on <a href="https://imaxlab.lt/en">IMAX LAB</a>.</p>